High Patch available CVSS 7.7

Siemens SIMATIC industrial PCs have a Secure Boot test-key flaw

CISA ICS AdvisoriesSiemens · Critical Manufacturing, Transportation Systems, EnergyCVE-2026-72895

What happened. A BIOS vendor test key sits in the UEFI Secure Boot key database. A local attacker with physical or administrative access could boot an operating system signed with it, bypassing Secure Boot. Siemens has released new versions.

Who is affected. SIMATIC IPC BX-21A before 31.01.13, IPC RW-543A before 1.1.4, and IPC227G/277G/277G PRO/327G/377G before 28.01.15.

What to do. Check whether you run the listed SIMATIC IPC models and update to the fixed versions Siemens has released.

Editor's reading

Forasset ownerOT security lead

Purdue level
  • L2
  • L1
Level 2, supervisory control (HMIs, SCADA, engineering workstations); Level 1, basic control (PLCs, RTUs, safety controllers)

Why: SIMATIC industrial PCs and panel PCs run HMI and control software on the plant floor, placing them mainly at L2, with some at L1.

Are you exposed?

Check your asset inventory for the listed SIMATIC IPC models and compare their firmware or BIOS versions with the fixed versions.