Industrial Cyber Briefby Girder · AI-powered industrial cyber security news
ReportsSubscribe

From the briefing of

Act today Critical Known exploited Patch available

Cisco firewall management flaw exploited by Interlock ransomware group

Cyber Kendra (via Google News)CiscoCVE-2026-20131

What happened. Cyber Kendra reports that CVE-2026-20131, a remote code execution flaw in Cisco Firewall Management Center (FMC), is being exploited by Interlock. The report gives no further detail.

Who is affected. Organisations running Cisco Firewall Management Center. Industrial sites that manage boundary firewalls with it are exposed, because it sits between office IT and plant networks.

What to do. Check whether you run Cisco FMC, apply the Cisco patch for CVE-2026-20131, and restrict access to the management interface.

When to act. Act today: Firewall and boundary operators: headline says Cisco FMC is exploited by Interlock; check and patch today.

Editor's reading

Forasset ownerOT security leadIT security

Purdue level
  • L4
  • L3.5
Level 4, enterprise IT; Level 3.5, the industrial DMZ

Why: Firewall Management Center controls boundary firewalls between enterprise IT (L4) and the industrial DMZ (L3.5), so a compromise affects the path into the plant.

Are you exposed?

Search the asset inventory for Cisco Firewall Management Center instances and check their software version and whether the management interface is reachable from untrusted networks.

If you cannot fix it yet
  • Restrict access to the FMC management interface to a small set of named administrator hosts.
  • Keep the FMC management interface off the internet and off the plant network until patched.
  • Require multi-factor authentication for every administrator account on the console.
Watch for
  • Unexpected logons or new administrator accounts on the FMC, especially from unfamiliar addresses.
  • Unplanned firewall policy changes or configuration pushes to boundary firewalls.

Inferred from the facts above, not stated by the source. Check it against your own site before acting.

Share

Source: Cyber Kendra (via Google News) (opens news.google.com)

Published by Industrial Cyber Brief · Editor: Abhinav Roy · Drafted by AI and checked by code: how this is made · Corrections