Plan ahead Medium Check your exposure

Wibu-Systems CodeMeter flaw affects several Endress+Hauser products

CERT@VDE advisoriesEndress+Hauser, Wibu-Systems CodeMeter

What happened. Advisory VDE-2025-105 reports a flaw in Wibu-Systems CodeMeter, up to version 7.60b, that affects multiple Endress+Hauser products. It can cause a heap buffer overflow, which may allow remote code execution under certain conditions.

Who is affected. Users of Endress+Hauser products that include Wibu-Systems CodeMeter up to 7.60b. The advisory excerpt does not list the individual products.

What to do. Check whether your Endress+Hauser products use CodeMeter up to 7.60b, and follow the vendor advisory VDE-2025-105 for fixes.

When to act. Plan ahead: Endress+Hauser and CodeMeter users: check affected versions and plan the fix into your next maintenance cycle.

Editor's reading

Forasset ownerOT security leadvendor/integrator

Purdue level
  • L3
  • L2
Level 3, site operations; Level 2, supervisory control (HMIs, SCADA, engineering workstations)

Why: CodeMeter is licensing software that runs on engineering and operations hosts, so affected products most likely sit on workstations and servers at L2 and L3. The advisory does not state levels.

Are you exposed?

Search your asset inventory for Endress+Hauser software and check the installed CodeMeter version for 7.60b or earlier.

If you cannot fix it yet
  • Restrict network access to the CodeMeter service to known hosts only.
  • Block CodeMeter traffic from the IT network and internet at the OT firewall.
  • Segment affected Endress+Hauser systems behind a firewall until fixes are applied.
Watch for
  • Unexpected inbound connections to the CodeMeter licensing service from unknown or IT-network hosts.
  • Crashes or restarts of the CodeMeter service, which may signal exploitation attempts.
ATT&CK for ICS
T0866Exploitation of Remote Services

Inferred from the facts above, not stated by the source. Check it against your own site before acting.

Share

Source: CERT@VDE advisories (opens certvde.com)

Published by Industrial Cyber Brief · Editor: Abhinav Roy · Drafted by AI and checked by code: how this is made · Corrections

More from this briefing

Read the full issue Executive report Get it by email

You confirm by email: look for a message from brief@mail.girder.in, in junk too if it is not in your inbox. You can leave in one click from any briefing. See today's issue · Privacy

Follow the Brief: Telegram · Bluesky · X