Siemens industrial software affected by Node.js Brotli decoder flaw

CISA ICS AdvisoriesSiemens, Node.js · manufacturingCVE-2026-111497

What happened. Node.js released updates on 21 October 2026 for a critical out-of-bounds write flaw in its Brotli decoder, called "Node2Shell". It could let a remote attacker run code. Siemens lists affected products and has released some new versions.

Who is affected. Users of SIMATIC BRAUMAT and SIMATIC SISTAR 8.2.0.1 to before 8.2.0.5, plus COMOS Walkinside, SIMATIC WinCC Companion and other Siemens products in all versions.

What to do. Check whether you run the listed Siemens products, update to the latest versions where Siemens has released them, and apply Siemens' mitigations where no fix exists yet.

When to act. Act today: CVE-2026-111497 is on CISA's list of known exploited flaws

Editor's reading

Forasset ownerOT security leadvendor/integrator

Purdue level
  • L3
  • L2
Level 3, site operations; Level 2, supervisory control (HMIs, SCADA, engineering workstations)

Why: The named products are engineering, visualisation and batch-control software (WinCC Companion, BRAUMAT, SISTAR) that run on workstations (L2) and site servers (L3).

Are you exposed?

Search your asset inventory for the listed Siemens products and versions, such as SIMATIC BRAUMAT or SISTAR between 8.2.0.1 and 8.2.0.5.

If you cannot fix it yet
  • Restrict network access to affected Siemens software to known engineering and operator hosts only.
  • Block internet access from hosts running the affected products.
  • Apply the specific mitigations Siemens recommends for products without a fix.
Watch for
  • Unexpected child processes or crashes in Node.js-based components on hosts running the affected Siemens software.
  • Unusual inbound connections to the Project Server Web Administration Tool or other web-facing Siemens components.

Inferred from the facts above, not stated by the source. Check it against your own site before acting.

Share

Source: CISA ICS Advisories (opens cisa.gov)

Published by Industrial Cyber Brief · Editor: Abhinav Roy · Drafted by AI and checked by code: how this is made · Corrections

More on Siemens Node.js Manufacturing CVE-2026-111497

More from this briefing

Read the full issue Executive report Get it by email

You confirm by email: look for a message from brief@mail.girder.in, in junk too if it is not in your inbox. You can leave in one click from any briefing. See today's issue · Privacy

Follow the Brief: Telegram · Bluesky · X