Industrial Cyber Briefby Girder · AI-powered industrial cyber security news
LiveSubscribe

From the briefing of

Act today Critical Check your exposure

Exposed refrigeration controllers, not quantum attacks, hit European supermarkets

CyberScoopfood, healthcare, building automation

What happened. CyberScoop reports attackers switched supermarket refrigeration into defrost mode across nine European countries, and some French blood banks were hit. The FBI and CISA warned that exposed refrigeration and temperature controllers were being targeted. Attackers used exposed admin interfaces, known flaws and default credentials.

Who is affected. The report names supermarkets in nine European countries and blood banks in France. US agencies warn of internet-exposed refrigeration and temperature controllers.

What to do. Remove refrigeration and temperature controller admin interfaces from the internet, change default credentials and patch known flaws.

When to act. Act today: Refrigeration and temperature controller operators: attacks disrupted stores; check that controllers are not…

Editor's reading

Forasset ownerOT security leadIT security

Purdue level
  • L2
  • L1
Level 2, supervisory control (HMIs, SCADA, engineering workstations); Level 1, basic control (PLCs, RTUs, safety controllers)

Why: Refrigeration and temperature controllers with admin interfaces are control-level devices, and exposure to the internet bypasses the layers above them.

Are you exposed?

Scan your public address ranges for refrigeration or temperature controller admin pages and check those devices for default credentials and unpatched flaws.

If you cannot fix it yet
  • Take controller admin interfaces off the internet and allow access only through a VPN with multi-factor authentication.
  • Change every factory default password on refrigeration and temperature controllers.
  • Segment controllers behind a firewall that blocks inbound connections from outside.
Watch for
  • Logons to refrigeration controller admin interfaces from unknown internet addresses.
  • Unplanned changes to temperature setpoints or defrost mode on controllers.
ATT&CK for ICS
T0883Internet Accessible DeviceT0831Manipulation of Control

Inferred from the facts above, not stated by the source. Check it against your own site before acting.

Share

Source: CyberScoop (opens cyberscoop.com)

Published by Industrial Cyber Brief · Editor: Abhinav Roy · Drafted by AI and checked by code: how this is made · Corrections